TUFBEND® U-Lamps (6" & 9" Leg Spacing)
TUFBEND® lamps ending in the suffix "CT"
are specifically designed for use in cold temperature applications and will perform
satisfactorily on existing ballasts at cold temperatures (<60°F). They are etched
"for cold temperature use only".
(2)
Lamp
Designation |
Nominal
Bent Length |
Actual
Bent
Length to Socket |
Lamp
Watts |
(3)
Rated
Life
(Hs) |
(1)
Lumens
Cool White |
Base |
Rod |
Shipping
Weight
6-pack |
| FTU9-36T12/HO |
18" |
15 13/16 |
48 |
9,000 |
2,750 |
FTU9/HO |
FTU36 |
6 |
| FTU9-48T12/HO |
24" |
21 13/16 |
60 |
12,000 |
4,000 |
FTU9/HO |
FTU48 |
8 |
| FTU9-60T12/HO |
30" |
27 13/16 |
75 |
12,000 |
5,125 |
FTU9/HO |
FTU60 |
10 |
| FTU9-72T12/HO |
36" |
33 13/16 |
87 |
12,000 |
6,125 |
FTU9/HO |
FTU72 |
12 |
| FTU9-84T12/HO |
42" |
39 13/16 |
100 |
12,000 |
7,400 |
FTU9/HO |
FTU84 |
13 |
| FTU9-96T12/HO/CT |
48" |
45 13/16 |
112 |
12,000 |
8,720 |
FTU9/HO |
FTU96 |
15 |
| FTU9-120T12/HO |
60" |
56 13/16 |
132 |
12,000 |
10,650 |
FTU9/HO |
FTU120 |
18 |
| FTU6-24T12/HO |
12" |
10 1/2 |
36 |
9,000 |
1,600 |
FTU6/HO |
FTU24 |
4 |
| FTU6-36T12/HO |
18" |
16 1/2 |
48 |
9,000 |
2,750 |
FTU6/HO |
FTU36 |
5 |
| FTU6-48T12/HO |
24" |
22 1/2 |
60 |
12,000 |
4,000 |
FTU6/HO |
FTU48 |
7 |
| FTU6-60T12/HO |
30" |
28 1/2 |
75 |
12,000 |
5,125 |
FTU6/HO |
FTU60 |
9 |
| FTU6-72T12/HO |
36" |
34 1/2 |
87 |
12,000 |
6,125 |
FTU6/HO |
FTU72 |
11 |
| FTU6-84T12/HO |
42" |
40 1/2 |
100 |
12,000 |
7,400 |
FTU6/HO |
FTU84 |
12 |
| FTU6-96T12/HO/CT |
48" |
46 1/2 |
112 |
12,000 |
8,720 |
FTU6/HO |
FTU96 |
14 |
| FTU6-120T12/HO |
60" |
57 |
132 |
12,000 |
10,650 |
FTU6/HO |
FTU120 |
16 |
(1) NORMAL LUMEN RATING:
Daylight, 83% of Cool White, Sign White. Rating are approximate initial
lumens at 100 hours
(2) Ballasts:
U-Lamp ballasted same as corresponding straight lamps
(3) RATED LIFE:
The rated life" of a statistically large group of lamps is defined as
the time when 50% of the lamps have failed and 50% have survived. This is based on 3 hours
of operation per start
|